EN(NZ)
Choose language
Change region
Choose your country Come visit our site in your country! Choose your region from the list below:
Choose language
Go
This product is not available for purchase by general public. Always follow the directions for use.
Lab

IPS e.max CAD for PrograMill HT C14 / 5
A3


686585
Go to downloads
All variants
Back to overview Request for quote
Variants
A1
686583
Add to cart
A2
686584
Add to cart
A3
686585
Add to cart
A3.5
686586
Add to cart
A4
686587
Add to cart
B1
686588
Add to cart
B2
686589
Add to cart
B3
686590
Add to cart
B4
686591
Add to cart
BL1
686579
Add to cart
BL2
686580
Add to cart
BL3
686581
Add to cart
BL4
686582
Add to cart
C1
686592
Add to cart
C2
686593
Add to cart
C3
686594
Add to cart
C4
686595
Add to cart
D2
686596
Add to cart
D3
686597
Add to cart
D4
686598
Add to cart
Description Ratings & Reviews (0)
Description
Description

Lithium disilicate glass-ceramics (LS2)

IPS e.max® CAD is the best-selling glass-ceramic[1] worldwide. The material enables the efficient fabrication of full-contour restorations. It is distinguished by its flexibility, versatile field of applications and processing options and its high strength of 530 MPa.[2]

Both its aesthetic properties and durability have been confirmed in everyday clinical practice.[3-5]

Processing options:
“Blue” restorations can be:

  • Polished and crystallised
  • Glazed and crystallised in a single step
  • Stained, glazed and crystallised in a single step

Types of restorations:

  • Minimally invasive crowns (1mm)[6]
  • Crowns
  • Three-unit bridges (up to the second premolar as the terminal abutment)
  • Implant-supported hybrid abutment restorations (hybrid abutments[7], hybrid abutment crowns)
  • Veneers and occlusal veneers
  • Inlays, onlays, partial crowns

Benefits:

  • Excellent aesthetics and high flexural strength of 530 MPa[2]
  • 97.2% survival rate of posterior crowns over a period of 10 years[8]
  • Efficient grinding and crystallisation of posterior crowns in only 19:17 minutes[9]
  • Broad spectrum of restorations for your chairside CAD/CAM applications
  • 10-year guarantee
  • Suitable for conventional, adhesive or self-adhesive cementation techniques

Block sizes[7]:

  • 6 (I12, C14, C16, B32, B40 and B40 L) and 2 abutment block sizes (A14, A16)

Translucency levels[7]:
Given their high translucency, HT blocks are ideally suited for the fabrication of small restorations (e.g. inlays, onlays). Restorations made from HT blocks blend in naturally with their surroundings due to their chameleon effect.[10]

  • 4 levels and 2 Impulse blocks (HT - High Translucency, MT - Medium Translucency, LT - Low Translucency, MO - Medium Opacity)

Shades[7]:

  • Comprehensive range of shades: in A-D and BL shades (the range of shades varies depending on the translucency level).

Authorised CAD/CAM systems:

Ivoclar:

  • PrograMill® PM3 / PM5 / PM7
  • Zenotec® Select Hybrid

Amann Girrbach:

  • Ceramill® mikro ic
  • Ceramill® motion 2 / motion 3 /drs
  • Ceramill® matik

Planmeca:

  • PlanMill® 30 S / 40 / 40 S

Dentsply Sirona:

  • inLab® MC XL / MC X5
  • CEREC® MC / MC X / MC XL / Primemill

 

[1] Based on global sales figures.
[2] Average biaxial flexural strength, Outcome after more than 10 years of ongoing quality testing, R&D Ivoclar, Schaan.
[3] Fasbinder D. J et al., Study report, 2017b.
[4] Rauch A et al., Clin. Oral Investig. 2018, 22, p. 1763-1769.
[5] Boldt J, Spitznagel F. A, Dtsch. Zahnaerztl. Z. 2017, 72 (4), p. 319-325.
[6] Long-term clinical evidence and the material’s high strength allows the recommendation for crowns with a minimum layer thickness of 1mm in combination with an adhesive cementation method.
[7] The offering varies, depending on the CAD/CAM system being used.
[8] The survival rate of monolithic IPS e.max CAD posterior crowns was evaluated with the Kaplan-Meier method. The failure rate refers to technical failures such as fractures and chipping, R&D Ivoclar, Schaan.
[9] Average grinding time of three posterior crowns, 08:07 minutes (CEREC Primemill, fast grinding mode), followed by superspeed crystallisation in the Programat CS6, 11:10 minutes (HT, MT, LT / glaze spray or polishing technique),
maximal two restorations, R&D Ivoclar, Schaan.

[10] At natural lighting conditions. LED-generated UV or UV-like light may result in a different impression.
 
CEREC®, inLab®, PlanMill® and ceramill® are not registered trademarks of Ivoclar Vivadent AG.

Ratings & Reviews (0)
No reviews on this product available. Be the first to write a review!
We can not publish your review if it contains:
Personal information Detailed information on prices, promotions, shipping and customer service Information about other companies and websites
Related products

Add to favorites

Please choose a list or create a new one to add the product to favorites.
Choose your list

Upgrade your account to perform your requested action

With your current account profile you cannot benefit from the full range of the Ivoclar Customer Portal functionality. Please upgrade your account for free.
mgctlbxN$MZP mgctlbxV$5.3.7 mgctlbxL$C