    IPS e.max CAD for PrograMill HT C14 / 5
    A4


    686587
    Go to downloads
    All variants
    Back to overview Request for quote
    Variants
    A1
    686583
    Add to cart
    A2
    686584
    Add to cart
    A3
    686585
    Add to cart
    A3.5
    686586
    Add to cart
    A4
    686587
    Add to cart
    B1
    686588
    Add to cart
    B2
    686589
    Add to cart
    B3
    686590
    Add to cart
    B4
    686591
    Add to cart
    BL1
    686579
    Add to cart
    BL2
    686580
    Add to cart
    BL3
    686581
    Add to cart
    BL4
    686582
    Add to cart
    C1
    686592
    Add to cart
    C2
    686593
    Add to cart
    C3
    686594
    Add to cart
    C4
    686595
    Add to cart
    D2
    686596
    Add to cart
    D3
    686597
    Add to cart
    D4
    686598
    Add to cart
    Description Ratings & Reviews (0)
    Description
    Description

    Lithium disilicate glass-ceramics (LS2)

    IPS e.max® CAD is the best-selling glass-ceramic[1] worldwide. The material enables the efficient fabrication of full-contour restorations. It is distinguished by its flexibility, versatile field of applications and processing options and its high strength of 530 MPa.[2]

    Both its aesthetic properties and durability have been confirmed in everyday clinical practice.[3-5]

    Processing options:
    “Blue” restorations can be:

    • Polished and crystallised
    • Glazed and crystallised in a single step
    • Stained, glazed and crystallised in a single step

    Types of restorations:

    • Minimally invasive crowns (1mm)[6]
    • Crowns
    • Three-unit bridges (up to the second premolar as the terminal abutment)
    • Implant-supported hybrid abutment restorations (hybrid abutments[7], hybrid abutment crowns)
    • Veneers and occlusal veneers
    • Inlays, onlays, partial crowns

    Benefits:

    • Excellent aesthetics and high flexural strength of 530 MPa[2]
    • 97.2% survival rate of posterior crowns over a period of 10 years[8]
    • Efficient grinding and crystallisation of posterior crowns in only 19:17 minutes[9]
    • Broad spectrum of restorations for your chairside CAD/CAM applications
    • 10-year guarantee
    • Suitable for conventional, adhesive or self-adhesive cementation techniques

    Block sizes[7]:

    • 6 (I12, C14, C16, B32, B40 and B40 L) and 2 abutment block sizes (A14, A16)

    Translucency levels[7]:
    Given their high translucency, HT blocks are ideally suited for the fabrication of small restorations (e.g. inlays, onlays). Restorations made from HT blocks blend in naturally with their surroundings due to their chameleon effect.[10]

    • 4 levels and 2 Impulse blocks (HT - High Translucency, MT - Medium Translucency, LT - Low Translucency, MO - Medium Opacity)

    Shades[7]:

    • Comprehensive range of shades: in A-D and BL shades (the range of shades varies depending on the translucency level).

    Authorised CAD/CAM systems:

    Ivoclar:

    • PrograMill® PM3 / PM5 / PM7
    • Zenotec® Select Hybrid

    Amann Girrbach:

    • Ceramill® mikro ic
    • Ceramill® motion 2 / motion 3 /drs
    • Ceramill® matik

    Planmeca:

    • PlanMill® 30 S / 40 / 40 S

    Dentsply Sirona:

    • inLab® MC XL / MC X5
    • CEREC® MC / MC X / MC XL / Primemill

     

    [1] Based on global sales figures.
    [2] Average biaxial flexural strength, Outcome after more than 10 years of ongoing quality testing, R&D Ivoclar, Schaan.
    [3] Fasbinder D. J et al., Study report, 2017b.
    [4] Rauch A et al., Clin. Oral Investig. 2018, 22, p. 1763-1769.
    [5] Boldt J, Spitznagel F. A, Dtsch. Zahnaerztl. Z. 2017, 72 (4), p. 319-325.
    [6] Long-term clinical evidence and the material’s high strength allows the recommendation for crowns with a minimum layer thickness of 1mm in combination with an adhesive cementation method.
    [7] The offering varies, depending on the CAD/CAM system being used.
    [8] The survival rate of monolithic IPS e.max CAD posterior crowns was evaluated with the Kaplan-Meier method. The failure rate refers to technical failures such as fractures and chipping, R&D Ivoclar, Schaan.
    [9] Average grinding time of three posterior crowns, 08:07 minutes (CEREC Primemill, fast grinding mode), followed by superspeed crystallisation in the Programat CS6, 11:10 minutes (HT, MT, LT / glaze spray or polishing technique),
    maximal two restorations, R&D Ivoclar, Schaan.

    [10] At natural lighting conditions. LED-generated UV or UV-like light may result in a different impression.
     
    CEREC®, inLab®, PlanMill® and ceramill® are not registered trademarks of Ivoclar Vivadent AG.

    Ratings & Reviews (0)
    No reviews on this product available. Be the first to write a review!
    We can not publish your review if it contains:
    Personal information Detailed information on prices, promotions, shipping and customer service Information about other companies and websites
    Related products

    Add to favorites

    Please choose a list or create a new one to add the product to favorites.
    Choose your list

    Upgrade your account to perform your requested action

    With your current account profile you cannot benefit from the full range of the Ivoclar Customer Portal functionality. Please upgrade your account for free.