EN(US)
Choose language
Change region
Choose your country Come visit our site in your country! Choose your region from the list below:
    Choose language
    Go
    Practice

    IPS e.max CAD HT C14/5 CEREC/InLab
    C2

    626417
    Go to downloads
    All variants
    Back to overview Request for quote
    Variants
    A1
    626407
    Add to cart
    A2
    626408
    Add to cart
    A3
    626409
    Add to cart
    A3.5
    626410
    Add to cart
    A4
    626411
    Add to cart
    B1
    626412
    Add to cart
    B2
    626413
    Add to cart
    B3
    626414
    Add to cart
    B4
    626415
    Add to cart
    BL1
    626427
    Add to cart
    BL2
    626428
    Add to cart
    BL3
    626429
    Add to cart
    BL4
    626430
    Add to cart
    C1
    626416
    Add to cart
    C2
    626417
    Add to cart
    C3
    626418
    Add to cart
    C4
    626419
    Add to cart
    D2
    626420
    Add to cart
    D3
    626421
    Add to cart
    D4
    626422
    Add to cart
    Description Ratings & Reviews (0)
    Description
    Description

    Lithium disilicate glass-ceramics (LS2)

    IPS e.max® CAD is the best-selling glass-ceramic[1] worldwide. The material enables the efficient fabrication of full-contour restorations. It is distinguished by its flexibility, versatile field of applications and processing options and its high strength of 530 MPa[2].

    Both its esthetic properties and durability have been confirmed in everyday clinical practice.[3-5].

    Processing options:
    “Blue” restorations can be:

    • polished and crystallized
    • glazed and crystallized in a single step
    • stained, glazed and crystallized in a single step

    Types of restorations:

    • Minimally invasive crowns (1 mm)[6]
    • crowns
    • Three-unit bridges (up to the second premolar as the terminal abutment)
    • Implant-supported hybrid abutment restorations (hybrid abutments[7], hybrid abutment crowns) – Veneers and occlusal veneers
    • Inlays, onlays, partial crowns

    Benefits:

    • Excellent esthetics and high flexural strength of 530 MPa[2]
    • 97.2% survival rate of posterior crowns over a period of 10 years[8]
    • Efficient grinding and crystallization of posterior crowns in only 19:17 minutes[9]
    • Broad spectrum of restorations for your chairside CAD/CAM applications
    • 10-year guarantee
    • Suitable for conventional, adhesive or self-adhesive cementation techniques

    Block sizes[7]:

    • 6 (I12, C14, C16, B32, B40 and B40 L) and 2 abutment block sizes (A14, A16)

    Translucency levels[7]:

    • 4 levels and 2 Impulse blocks (HT – High Translucency, MT – Medium Translucency, LT – Low Translucency, MO – Medium Opacity)

    Shades[7]:

    • Comprehensive range of shades: in A–D and BL shades (the range of shades varies depending on the translucency level), see page 60–65.

    Authorized CAD/CAM systems:

    • Ivoclar:
      • PrograMill® PM3 / PM5 / PM7
      • Zenotec® select hybrid
    • Amann Girrbach:
      • ceramill® mikro ic,
      • ceramill® motion 2 / motion 3 /drs
      • ceramill® matik
    • Planmeca:
      • PlanMill® 30 S / 40 / 40 S
    • Dentsply Sirona:
      • inLab® MC XL / MC X5
      • CEREC® MC / MC X / MC XL / Primemill

    [1] Based on global sales figures.
    [2] Average biaxial flexural strength; outcome after more than 10 years of ongoing quality testing, R&D Ivoclar, Schaan.
    [3] Fasbinder D. J et al., Study report, 2017b.
    [4] Rauch A et al., Clin. Oral Investig. 2018, 22, p. 1763-1769.
    [5] Boldt J, Spitznagel F. A, Dtsch. Zahnaerztl. Z. 2017, 72 (4), p. 319-325.
    [6] Long-term clinical evidence and the material’s high strength allows the recommendation for crowns with a minimum layer thickness of 1 mm in combination with an adhesive cementation method.
    [7] The offering varies, depending on the CAD/CAM system being used.
    [8] The survival rate of monolithic IPS e.max CAD posterior crowns was evaluated with the Kaplan-Meier method. The failure rate refers to technical failures such as fractures and chipping, R&D Ivoclar, Schaan.
    [9] Average grinding time of three posterior crowns, 08:07 minutes (CEREC Primemill, fast grinding mode), followed by superspeed crystallization in the Programat CS6, 11:10 minutes (HT, MT, LT / glaze spray or polishing technique), maximal two restorations, R&D Ivoclar, Schaan.

    CEREC®, inLab®, PlanMill® und ceramill® are not registered trademarks of Ivoclar Vivadent AG.

    Ratings & Reviews (0)
    No reviews on this product available. Be the first to write a review!
    We can not publish your review if it contains:
    Personal information Detailed information on prices, promotions, shipping and customer service Information about other companies and websites

    Add to favorites

    Please choose a list or create a new one to add the product to favorites.
    Choose your list

    Upgrade your account to perform your requested action

    With your current account profile you cannot benefit from the full range of the Ivoclar Customer Portal functionality. Please upgrade your account for free.